Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
J Clin Microbiol ; 60(5): e0188421, 2022 05 18.
Article in English | MEDLINE | ID: covidwho-1932613

ABSTRACT

Home testing for infectious disease has come to the forefront during the COVID-19 pandemic. There is now considerable commercial interest in developing complete home tests for a variety of viral and bacterial pathogens. However, the regulatory science around home infectious disease test approval and procedures that test manufacturers and laboratory professionals will need to follow have not yet been formalized by the U.S. Food and Drug Administration (FDA), with the exception of Emergency Use Authorization (EUA) guidance for COVID-19 tests. We describe the state of home-based testing for influenza with a focus on sample-to-result home tests, discuss the various regulatory pathways by which these products can reach populations, and provide recommendations for study designs, patient samples, and other important features necessary to gain market access. These recommendations have potential application for home use tests being developed for other viral respiratory infections, such as COVID-19, as guidance moves from EUA designation into 510(k) requirements.


Subject(s)
COVID-19 , Influenza, Human , COVID-19/diagnosis , Humans , Influenza, Human/diagnosis , Laboratories , Pandemics , SARS-CoV-2
2.
Analyst ; 147(14): 3315-3327, 2022 Jul 12.
Article in English | MEDLINE | ID: covidwho-1908309

ABSTRACT

The COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of virologic failure and HIV-associated illness. Often this population is at high risk for exposure to SARS-CoV-2 infection, and once infected, for severe disease. Therefore, close monitoring of HIV plasma viral load (VL) and screening for SARS-CoV-2 infection are needed. We developed a non-proprietary method to isolate RNA from plasma, nasal secretions (NS), or both. The extracted RNA is then submitted to RT-qPCR to estimate the VL and classify HIV/SARS-CoV-2 status (i.e., HIV virologic failure or suppressed; SARS-CoV-2 as positive, presumptive positive, negative, or indeterminate). In contrived samples, the in-house RNA extraction workflow achieved a detection limit of 200-copies per mL for HIV RNA in plasma and 100-copies per mL for SARS-CoV-2 RNA in NS. Similar detection limits were observed for HIV and SARS-CoV-2 in pooled plasma/NS contrived samples. When comparing in-house with standard extraction methods, we found high agreement (>0.91) between input and measured RNA copies for HIV LTR in contrived plasma; SARS-CoV-2 N1/N2 in contrived NS; and LTR, N1, and N2 in pooled plasma/NS samples. We further evaluated this workflow on 133 clinical specimens: 40 plasma specimens (30 HIV-positive), 67 NS specimens (31 SARS-CoV-2-positive), and 26 combined plasma/NS specimens (26 HIV-positive with 10 SARS-CoV-2-positive), and compared the results obtained using the in-house RNA extraction to those using a commercial kit (standard extraction method). The in-house extraction and standard extraction of clinical specimens were positively correlated: plasma HIV VL (R2 of 0.81) and NS SARS-CoV-2 VL (R2 of 0.95 and 0.99 for N1 and N2 genes, respectively); and pooled plasma/NS HIV VL (R2 of 0.71) and SARS-CoV-2 VL (R2 of 1 both for N1 and N2 genes). Our low-cost molecular test workflow ($1.85 per pooled sample extraction) for HIV RNA and SARS-CoV-2 RNA could serve as an alternative to current standard assays ($12 per pooled sample extraction) for laboratories in low-resource settings.


Subject(s)
COVID-19 , HIV Infections , COVID-19/diagnosis , HIV Infections/diagnosis , Humans , Pandemics , RNA, Viral/analysis , SARS-CoV-2/genetics , Sensitivity and Specificity , Viral Load/methods , Workflow
3.
Microbiol Spectr ; 10(4): e0158321, 2022 08 31.
Article in English | MEDLINE | ID: covidwho-1901937

ABSTRACT

The increasing prevalence of variant lineages during the COVID-19 pandemic has the potential to disrupt molecular diagnostics due to mismatches between primers and variant templates. Point-of-care molecular diagnostics, which often lack the complete functionality of their high-throughput laboratory counterparts, are particularly susceptible to this type of disruption, which can result in false-negative results. To address this challenge, we have developed a robust Loop Mediated Isothermal Amplification assay with single tube multiplexed multitarget redundancy and an internal amplification control. A convenient and cost-effective target-specific fluorescence detection system allows amplifications to be grouped by signal using adaptable probes for pooled reporting of SARS-CoV-2 target amplifications or differentiation of the Internal Amplification Control. Over the course of the pandemic, primer coverage of viral lineages by the three redundant sub-assays has varied from assay to assay as they have diverged from the Wuhan-Hu-1 isolate sequence, but aggregate coverage has remained high for all variant sequences analyzed, with a minimum of 97.4% (Variant of Interest: Eta). In three instances (Delta, Gamma, Eta), a high-frequency mismatch with one of the three sub-assays was observed, but overall coverage remained high due to multitarget redundancy. When challenged with extracted human samples the multiplex assay showed 87% or better sensitivity (of 30 positive samples), with 100% sensitivity for samples containing greater than 30 copies of viral RNA per reaction (of 21 positive samples), and 100% specificity (of 60 negative samples). These results are further evidence that conventional laboratory methodologies can be leveraged at the point of care for robust performance and diagnostic stability over time. IMPORTANCE The COVID-19 pandemic has had tremendous impact, and the ability to perform molecular diagnostics in resource limited settings has emerged as a key resource for mitigating spread of the disease. One challenge in COVID-19 diagnosis, as well as other viruses, is ongoing mutation that can allow viruses to evade detection by diagnostic tests. We developed a test that detects multiple parts of the virus genome in a single test to reduce the chance of missing a virus due to mutation, and it is designed to be simpler and faster than typical laboratory tests while maintaining high sensitivity. This capability is enabled by a novel fluorescent probe technology that works with a simple constant temperature reaction condition.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques/methods , Fluorescent Dyes , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques , Pandemics , SARS-CoV-2/genetics , Sensitivity and Specificity
4.
Anal Chem ; 94(20): 7278-7285, 2022 05 24.
Article in English | MEDLINE | ID: covidwho-1829922

ABSTRACT

The COVID-19 pandemic is among the greatest health and socioeconomic crises in recent history. Although COVID-19 vaccines are being distributed, there remains a need for rapid testing to limit viral spread from infected individuals. We previously identified the SARS-CoV-2 spike protein N-terminal domain (NTD) binding DNA aptamer 1 (SNAP1) for detection of SARS-CoV-2 virus by aptamer-antibody sandwich enzyme-linked immunoassay (ELISA) and lateral flow assay (LFA). In this work, we identify a new aptamer that also binds at the NTD, named SARS-CoV-2 spike protein NTD-binding DNA aptamer 4 (SNAP4). SNAP4 binds with high affinity (<30 nM) for the SARS-CoV-2 spike protein, a 2-fold improvement over SNAP1. Furthermore, we utilized both SNAP1 and SNAP4 in an aptamer sandwich LFA (AptaFlow), which detected SARS-CoV-2 UV-inactivated virus at concentrations as low as 106 copies/mL. AptaFlow costs <$1 per test to produce, provides results in <1 h, and detects SARS-CoV-2 at concentrations that indicate higher viral loads and a high probability of contagious transmission. AptaFlow is a potential approach for a low-cost, convenient antigen test to aid the control of the COVID-19 pandemic.


Subject(s)
Aptamers, Nucleotide , COVID-19 , Antibodies, Viral , Aptamers, Nucleotide/chemistry , COVID-19/diagnosis , COVID-19 Vaccines , Humans , Pandemics , SARS-CoV-2 , Spike Glycoprotein, Coronavirus
5.
J Clin Microbiol ; 60(3): e0207021, 2022 03 16.
Article in English | MEDLINE | ID: covidwho-1744136

ABSTRACT

At-home testing with rapid diagnostic tests (RDTs) for respiratory viruses could facilitate early diagnosis, guide patient care, and prevent transmission. Such RDTs are best used near the onset of illness when viral load is highest and clinical action will be most impactful, which may be achieved by at-home testing. We evaluated the diagnostic accuracy of the QuickVue Influenza A+B RDT in an at-home setting. A convenience sample of 5,229 individuals who were engaged with an on-line health research platform were prospectively recruited throughout the United States. "Flu@home" test kits containing a QuickVue RDT and reference sample collection and shipping materials were prepositioned with participants at the beginning of the study. Participants responded to daily symptom surveys. If they reported experiencing cough along with aches, fever, chills, and/or sweats, they used their flu@home kit following instructions on a mobile app and indicated what lines they saw on the RDT. Of the 976 participants who met criteria to use their self-collection kit and completed study procedures, 202 (20.7%) were positive for influenza by qPCR. The RDT had a sensitivity of 28% (95% CI = 21 to 36) and specificity of 99% (98 to 99) for influenza A, and 32% (95% CI = 20 to 46) and 99% (95% CI = 98 to 99), for influenza B. Our results support the concept of app-supported, prepositioned at-home RDT kits using symptom-based triggers, although it cannot be recommended with the RDT used in this study. Further research is needed to determine ways to improve the accuracy and utility of home-based testing for influenza.


Subject(s)
Influenza, Human , Mobile Applications , Diagnostic Tests, Routine , Fever , Humans , Influenza, Human/diagnosis , Postal Service , Sensitivity and Specificity
6.
Sci Adv ; 7(51): eabj1281, 2021 Dec 17.
Article in English | MEDLINE | ID: covidwho-1575234

ABSTRACT

RNA amplification tests sensitively detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but their complexity and cost are prohibitive for expanding coronavirus disease 2019 (COVID-19) testing. We developed "Harmony COVID-19," a point-of-care test using inexpensive consumables, ready-to-use reagents, and a simple device. Our ready-to-use, multiplexed reverse transcription, loop-mediated isothermal amplification (RT-LAMP) can detect down to 0.38 SARS-CoV-2 RNA copies/µl and can report in 17 min for high­viral load samples (5000 copies/µl). Harmony detected 97 or 83% of contrived samples with ≥0.5 viral particles/µl in nasal matrix or saliva, respectively. Evaluation in clinical nasal specimens (n = 101) showed 100% detection of RNA extracted from specimens with ≥0.5 SARS-CoV-2 RNA copies/µl, with 100% specificity in specimens positive for other respiratory pathogens. Extraction-free analysis (n = 29) had 95% success in specimens with ≥1 RNA copies/µl. Usability testing performed first time by health care workers showed 95% accuracy.

7.
BMC Infect Dis ; 21(1): 617, 2021 Jun 29.
Article in English | MEDLINE | ID: covidwho-1285993

ABSTRACT

BACKGROUND: Seasonal influenza leads to significant morbidity and mortality. Rapid self-tests could improve access to influenza testing in community settings. We aimed to evaluate the diagnostic accuracy of a mobile app-guided influenza rapid self-test for adults with influenza like illness (ILI), and identify optimal methods for conducting accuracy studies for home-based assays for influenza and other respiratory viruses. METHODS: This cross-sectional study recruited adults who self-reported ILI online. Participants downloaded a mobile app, which guided them through two low nasal swab self-samples. Participants tested the index swab using a lateral flow assay. Test accuracy results were compared to the reference swab tested in a research laboratory for influenza A/B using a molecular assay. RESULTS: Analysis included 739 participants, 80% were 25-64 years of age, 79% female, and 73% white. Influenza positivity was 5.9% based on the laboratory reference test. Of those who started their test, 92% reported a self-test result. The sensitivity and specificity of participants' interpretation of the test result compared to the laboratory reference standard were 14% (95%CI 5-28%) and 90% (95%CI 87-92%), respectively. CONCLUSIONS: A mobile app facilitated study procedures to determine the accuracy of a home based test for influenza, however, test sensitivity was low. Recruiting individuals outside clinical settings who self-report ILI symptoms may lead to lower rates of influenza and/or less severe disease. Earlier identification of study subjects within 48 h of symptom onset through inclusion criteria and rapid shipping of tests or pre-positioning tests is needed to allow self-testing earlier in the course of illness, when viral load is higher.


Subject(s)
Influenza A virus/immunology , Influenza B virus/immunology , Influenza, Human/diagnosis , Mobile Applications , Self-Testing , Adult , Cross-Sectional Studies , Data Accuracy , Enzyme-Linked Immunosorbent Assay/methods , Feasibility Studies , Female , Humans , Influenza, Human/virology , Male , Middle Aged , Sensitivity and Specificity
8.
JMIR Res Protoc ; 10(6): e28094, 2021 Jun 21.
Article in English | MEDLINE | ID: covidwho-1278300

ABSTRACT

BACKGROUND: Tuberculosis (TB) is an urgent global health threat and the world's deadliest infectious disease despite being largely curable. A critical challenge is to ensure that patients adhere to the full course of treatment to prevent the continued spread of the disease and development of drug-resistant disease. Mobile health interventions hold promise to provide the required adherence support to improve TB treatment outcomes. OBJECTIVE: This study aims to evaluate the effectiveness of the TB treatment support tools (TB-TSTs) intervention on treatment outcomes (success and default) and to assess patient and provider perceptions of the facilitators and barriers to TB-TSTs implementation. METHODS: The TB-TSTs study is an open-label, randomized controlled trial with 2 parallel groups in which 400 adult patients newly diagnosed with TB will be randomly assigned to receive usual care or usual care plus TB-TSTs. Participants will be recruited on a rolling basis from 4 clinical sites in Argentina. The intervention consists of a smartphone progressive web app, a treatment supporter (eg, TB nurse, physician, or social worker), and a direct adherence test strip engineered for home use. Intervention group participants will report treatment progress and interact with a treatment supporter using the app and metabolite urine test strip. The primary outcome will be treatment success. Secondary outcomes will include treatment default rates, self-reported adherence, technology use, and usability. We will assess patients' and providers' perceptions of barriers to implementation and synthesize lessons learned. We hypothesize that the TB-TSTs intervention will be more effective because it allows patients and TB supporters to monitor and address issues in real time and provide tailored support. We will share the results with stakeholders and policy makers. RESULTS: Enrollment began in November 2020, with a delayed start due to the COVID-19 pandemic, and complete enrollment is expected by approximately July 2022. Data collection and follow-up are expected to be completed 6 months after the last patient is enrolled. Results from the analyses based on the primary end points are expected to be submitted for publication within a year of data collection completion. CONCLUSIONS: To our knowledge, this randomized controlled trial will be the first study to evaluate a patient-centered remote treatment support strategy using a mobile tool and a home-based direct drug metabolite test. The results will provide robust scientific evidence on the effectiveness, implementation, and adoption of mobile health tools. The findings have broader implications not only for TB adherence but also more generally for chronic disease management and will improve our understanding of how to support patients facing challenging treatment regimens. TRIAL REGISTRATION: ClinicalTrials.gov NCT04221789; https://clinicaltrials.gov/ct2/show/NCT04221789. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/28094.

10.
EBioMedicine ; 64: 103236, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-1083288

ABSTRACT

BACKGROUND: Detection of SARS-CoV-2 infections is important for treatment, isolation of infected and exposed individuals, and contact tracing. RT-qPCR is the "gold-standard" method to sensitively detect SARS-CoV-2 RNA, but most laboratory-developed RT-qPCR assays involve complex steps. Here, we aimed to simplify RT-qPCR assays by streamlining reaction setup, eliminating RNA extraction, and proposing reduced-cost detection workflows that avoid the need for expensive qPCR instruments. METHOD: A low-cost RT-PCR based "kit" was developed for faster turnaround than the CDC developed protocol. We demonstrated three detection workflows: two that can be deployed in laboratories conducting assays of variable complexity, and one that could be simple enough for point-of-care. Analytical sensitivity was assessed using SARS-CoV-2 RNA spiked in simulated nasal matrix. Clinical performance was evaluated using contrived human nasal matrix (n = 41) and clinical nasal specimens collected from individuals with respiratory symptoms (n = 110). FINDING: The analytical sensitivity of the lyophilised RT-PCR was 10 copies/reaction using purified SARS-CoV-2 RNA, and 20 copies/reaction when using direct lysate in simulated nasal matrix. Evaluation of assay performance on contrived human matrix showed 96.7-100% specificity and 100% sensitivity at ≥20 RNA copies. A head-to-head comparison with the standard CDC protocol on clinical specimens showed 83.8-94.6% sensitivity and 96.8-100% specificity. We found 3.6% indeterminate samples (undetected human control), lower than 8.1% with the standard protocol. INTERPRETATION: This preliminary work should support laboratories or commercial entities to develop and expand access to Covid-19 testing. Software guidance development for this assay is ongoing to enable implementation in other settings. FUND: USA NIH R01AI140845 and Seattle Children's Research Institute.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/genetics , Humans , Sensitivity and Specificity
11.
medRxiv ; 2020 Sep 30.
Article in English | MEDLINE | ID: covidwho-835251

ABSTRACT

The rapid spread of SARS-CoV-2 has gravely impacted societies around the world. Outbreaks in different parts of the globe are shaped by repeated introductions of new lineages and subsequent local transmission of those lineages. Here, we sequenced 3940 SARS-CoV-2 viral genomes from Washington State to characterize how the spread of SARS-CoV-2 in Washington State (USA) was shaped by differences in timing of mitigation strategies across counties, as well as by repeated introductions of viral lineages into the state. Additionally, we show that the increase in frequency of a potentially more transmissible viral variant (614G) over time can potentially be explained by regional mobility differences and multiple introductions of 614G, but not the other variant (614D) into the state. At an individual level, we see evidence of higher viral loads in patients infected with the 614G variant. However, using clinical records data, we do not find any evidence that the 614G variant impacts clinical severity or patient outcomes. Overall, this suggests that at least to date, the behavior of individuals has been more important in shaping the course of the pandemic than changes in the virus.

SELECTION OF CITATIONS
SEARCH DETAIL